D GB F E109917-02.2015-DGbFEIengineering for a better world GEA Refrigeration TechnologiesGEA Bock Compressor HGX12P CO2Assembly instructionsHGX12P/3
10 D GB F E09917-02.2015-DGbFEIFig. 12Rigid fixed pointAs short as possible4.5 LayingsuctionandpressurelinesINFO! Proper layout of the suction
D GB F E1109917-02.2015-DGbFEIValve spindle sealReleaseTightenFig. 13Fig. 144| Compressor assembly Before opening or closing the shut-off valve, rel
12 D GB F E09917-02.2015-DGbFEI5| Electrical connection 5 Electrical connection DANGER! Highvoltage!Riskofelectricshock!Onlycarryout
D GB F E1309917-02.2015-DGbFEI5| Electrical connection 5.2 Connection of the driving motorThe compressor is designed with a motor for star-delta c
14 D GB F E09917-02.2015-DGbFEI
D GB F E1509917-02.2015-DGbFEI
16 D GB F E09917-02.2015-DGbFEI5| Electrical connection PTC1PTC2Terminal boxFig. 18Temperature monitoring connections: Motor winding: Terminals
D GB F E1709917-02.2015-DGbFEI5.7 Oil sump heater(accessories)ATTENTION! The oil sump heater must generally be connected and operated.Inorderto
18 D GB F E09917-02.2015-DGbFEI6| CommissioningWARNING! Whenthecompressorisnotrunning,dependingonambient temperatureandamountofrefriger
D GB F E1909917-02.2015-DGbFEI6| Commissioning Make sure that the suction and pressure line shut-off valves are open. Fillingtheliquidrefrigeran
2 D GB F E09917-02.2015-DGbFEIAbout these instructionsRead these instructions before assembly and before using the compressor. This will avoid misunde
20 D GB F E09917-02.2015-DGbFEI6| CommissioningThecompressoristtedwithtwodecompressionvalves.Onevalveeachonthesuctionanddischargeside
D GB F E2109917-02.2015-DGbFEI6.9 Connection of oil level regulatorThe connection "O" is provided for installing an oil level regulator. A
22 D GB F E09917-02.2015-DGbFEI7| Maintenance7.5 Extract from the lubricants tableOnlyusegenuineGEABockspareparts!7.3 Spare parts recommendati
D GB F E2309917-02.2015-DGbFEI7.6 DecommissioningClose the shut-off valves on the compressor. CO2 does not need to be recycled and can therefore be b
24 D GB F E09917-02.2015-DGbFEI8| Technical dataTypeNo. of cylindersDisplacement50 / 60 Hz(1450/1740rpm)Electrical dataWeightConnections Oil ch
D GB F E2509917-02.2015-DGbFEI9| Dimensions and connectionsSVDVSuction lineDischarge line see technical data, Chapter 8A*Connection
26 D GB F E09917-02.2015-DGbFEI10| Declaration of conformity and installationDECLARATIONOFCONFORMITYCE06for using the compressors within the Europ
D GB F E2709917-02.2015-DGbFEIDear customer,GEABockcompressorsaretop-quality,reliableandservice-friendlyqualityproducts. Ifyouhaveanyqu
28 D GB F E09917-02.2015-DGbFEI09917-02.2015-DGbFEI © GEA Group AG. All rights reserved.GEA Refrigeration TechnologiesGEA Bock GmbHBenzstraße 7, 7263
D GB F E309917-02.2015-DGbFEIContents Page 1 Safety 4 1.1 Identicationofsafetyinstructions 1.2 Qualicationsrequiredof
4 D GB F E09917-02.2015-DGbFEI WARNING! DANGER OF SUFFOCATION! NeverreleasesignicantvolumesofCO2 or the entire contents of the system into
D GB F E509917-02.2015-DGbFEI1| SafetyThese assembly instructions describe the standard version of the HGX12P -CO2 manufactured by GEA Bock. The comp
6 D GB F E09917-02.2015-DGbFEIName plateFig. 1Fig. 2Oil sight glassValve plate Cylinder coverDischarge shut-off valveOil pumpTerminal boxSuction shu
D GB F E709917-02.2015-DGbFEI2| Product description/HG 21 P75-4CO2X2.2 Name plate (example)2.3 Typekey (example)¹) HG - Hermetic Gas-Cooled (suct
8 D GB F E09917-02.2015-DGbFEI3| Areas of application Thecompressorsarelledatthefactorywiththefollowingoiltype:GEABockC85E(only
D GB F E909917-02.2015-DGbFEI4| Compressor assembly4.3 Pipe connectionsINFO! Newcompressorsarefactory-lledwithinertgas(3barnitrogen). L
Kommentare zu diesen Handbüchern